LY72 |
Specifications by application
|
Applications as gauge (set axis labels A, B, and C) |
Applications as scale (set axis labels X, Y, & Z) |
|
1~3axis |
|
7 digits and minus display, Color amber |
|
Current (1st axis, 2nd axis, addition axis), maximum, minimum and peak-to-peak values |
Current (1st axis, 3rd axis, addition axis) |
|
Standard : 0.1 μm, 0.5 μm, 1 μm, 5 μm, 10 μm, 1 s, 10 s, 1 min, 10 min
Expanded : 100 μm, 50 μm, 25 μm, 20 μm, 2 μm, 0.05 μm, and 1 degree can be added.
|
| Display resolution |
Measuring unit input resolution or higher and supported inch units |
| Input signal |
A/B quadrature signal, Z signal (Conforms to EIA-422) |
|
Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data |
|
Current value reset, Alarm cancel |
| Restart |
Restart of peak value calculation for each axis/all axes |
- |
|
It is possible to store/edit up to three values for each axis. |
Master calibration function
|
The master calibration value is relocated when going past the reference point after the power is turned on. |
- |
| Reference point operations |
It is possible to store/edit one value for each axis (when not using the master calibration function). |
| Hold function |
Selectable from latch and pause
Latch : Display held while latched (Display hold)
Pause : Peak calculation stopped while paused (Peak calculation hold)
|
Display hold |
|
A fixed compensation amount is applied to the measuring unit's count value. Compensation amount Standard: ±600 μm/m (Expanded: ±1000 μm/m) |
|
0.100000~9.999999 |
|
|
Data format: All axes on same line/New line for each axis Peak-to-peak value
Transfer rate:38400/19200/9600/4800/2400/1200bps
Parity: None/Odd/Even, Stop bit : 1 or 2, Data length: 8 bits or 7 bits
|
| Timer output |
OFF/0.2/0.5/1/5/10/30/60/300 |
- |
| Output data |
Current value/Maximum value/Minimum value Peak-to-Peak value |
Current value |
|
DC 12 V Rating 0.75 A Max. 1 A AC 100 V to 240 V ±10 % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option |
|
MAX. 32 VA connected at the AC adaptor. |
|
Operating: 0~40°C (non condensing) Storage: -20~60°C (non condensing) |
|
Approx. 1.5kg |
| CAD Dimensions for LY72 |